Molecular sieves commonly used in China's industrial production are divided into 3A, 4A, 5A, 13X and other molecular sieves, and the service life is related to the environmental humidity, trial pressure, filling compactness, etc., and can be used for 2-3 years under normal circumstances. If it is well managed, it can be used for more than 5 years without major production accidents.
For manufacturers who use molecular sieve products, everyone is concerned about a question, "how to extend the service life of molecular sieve?" In fact, there are two main factors that affect the life of molecular sieve, that is, correct use and frequent maintenance of it in use.
Correct use of molecular sieve, in the molecular sieve adsorption process, we should operate in strict accordance with the design value of the adsorption equipment, and strictly follow the key indicators such as flow, temperature, pressure, and switching time of the feed set by the system. These are very important. A well-designed and properly used zeolite adsorption device should be used for between 24'000-40'000 hours, about 3 to 5 years. Freshly purchased molecular sieves, unless explicitly indicated to have been activated and stored sealed. Otherwise, it still needs to be baked at high temperature for activation, and 500 degrees is generally enough. The activation is carried out in a muffle furnace, in which cylinder air or nitrogen is passed, and then naturally cooled to about 100 degrees under ventilated conditions, and then taken out and transferred to a dryer for closed storage.
Use the daily maintenance of molecular sieves in progress: choose the right molecular sieve, reduce the water content in the air, prevent the pollution of lubricating oil, correct heating and regeneration, timely removal of powder, etc. In addition, in the molecular sieve regeneration process, it is not suitable to use room temperature air to regenerate the molecular sieve bed for the dry gas of the product treated by molecular sieve or the low dew point gas of other processes, especially in the stage of blowing cold, which is often counterproductive. The heating in the regeneration process should be carried out slowly in sections, not directly heated to 200-300 degrees, the bed of the regenerated molecular sieve should be directly reversed, and the regeneration gas must stay at about 150 degrees when heating. The time of heating and regeneration is also an important point that needs to be paid attention to.
Generally, it needs to be replaced when it expires according to the instructions for use, but if it is water ingress, it needs to be replaced at any time according to the situation, because after water immersion, even if special regeneration is adopted, it will cause the molecular sieve to break under the impact of air flow, and it will be troublesome to block the heat exchanger. In addition, it depends on whether the moisture and carbon dioxide content of the purified gas are within the index, and if the index is exceeded, it needs to be replaced.